CHOICE BETWEEN PLATE AND PACKED COLUMN


The choice between use of tray column or a packed column for a given mass transfer operation should, theoretically, be based on a detail cost analysis for the two types of contactors. However, the decision can be made on the basis of a qualitative analysis of relative advantages and disadvantages, eliminating the need for a detailed cost comparison.
Which are:
1.     Because of liquid dispersion difficulties in packed columns, the design of tray column is considerably more reliable.
2.     Tray columns can be designed to handle wide ranges liquid rates without flooding.
3.     If the operation involves liquids that contain dispersed solids, use of a tray column is preferred because the plates are more accessible for cleaning.
4.     For non-foaming systems the plate column is preferred.
5.     If periodic cleaning is required, man holes        will be provided for cleaning. In packed columns packing must be removed before cleaning.
6.     For large column heights, weight of the packed column is more than plate column.
7.     Design information for plate column is more readily available and more reliable than that for packed column.
8.     Inter stage cooling can be provided to remove heat of reaction or solution in plate column.
9.     When temperature change is involved, packing may be damaged.

10.  Random-packed columns generally are not designed with diameters larger than 1.5 m, and diameters of commercial tray column are seldom less than 0.67m.

As my system is non foaming and diameter calculated is larger than 1.5m so I am going to use tray column.
Also as average temperature calculated for my distillation column is higher that is approximately equal to 98oc. So I prefer Tray column.

PLATE CONTACTORS:

                                             Cross flow plate are the most commonly used plate contactor in distillation. In which liquid flows downward and vapours flow upward. The liquid move from plate to plate via down comer. A certain level of liquid is maintained on the plates by weir. Other types of plate are used which have no down comer (non-cross flow) the liquid showering down the column through large opening in the plates (called shower plates). Used when low pressure drop is required.
Three basic types of cross flow trays used are


(1)               Sieve Plate (Perforated Plate)
(2)               Bubble Cap Plates
(3)               Valve plates (floating cap plates)

I prefer sieve plate because:

(1) Their fundamentals are well established, entailing low risk.
(2) The trays are low in cost relative to many other types of trays.
(3) They can easily handle wide variations in flow rates.
(4) They are lighter in weight. It is easier and cheaper to install.
(5) Pressure drop is low as compared to bubble cap trays.
(6) Peak efficiency is generally high.
(7) Maintenance cost is reduced due to the ease of cleaning.

5 comments:

  1. Very good work on such topic. When I started to read blog I was occupied with the best way you current such great topic. By the way in which might you please publish extra article on such topic? I really respect it. Pressurized Equipment || Non Pressurized Equipment || Storage Tanks

    ReplyDelete
  2. It is so amazing post. I have never read any interesting post before. I really like this. Thanks for the author sharing very informative resource. If possible, I will share this post to everyone. Reaction Kettles || Process Piping || Site Fabrication

    ReplyDelete
  3. Nice blog, I think packed column is better than plate column.It vital role in chemical packing and distillation column. According to my knowledge finepac is best Packed Column manufacturer in world.

    ReplyDelete
  4. I found this is an informative and interesting post so i think so it is very useful and knowledgeable. I would like to thank you for the efforts you have made in writing this article. website

    ReplyDelete